Logo
service spacer

Tower Services

Annual Maintenance Program

Programs are available in four basic plans. These programs can be packaged to meet any specific requirement. The programs can also be set up on various time frames for easy budgeting of your maintenance dollars.

Plumb & Tension

Tower's vertical alignment is set and guy wires tensioned to manufacturers specifications. This service is a basic tower maintenance procedure to ensure proper operation and compliance with EIA TIA 222-F specifications.

Tower Re-Guying

Preferred Tank & Tower offers complete re-guying of all types of towers. Older towers with corroded or pitted guy wires can usually be repaired for a fraction of the cost of a complete tower replacement. All materials used are in complicance with applicable EIA TIA 222-F, AISC and ANSI standards for quality.

Guy Wire Greasing and Coating

This service is provided to prolong the life of galvanized EHS guy wires by coating or pressure injecting the wires with a rust inhibitive coating. Special coatings are available such as Ice Phobic, which hardens and prevents icing on guy wires.

Painting

Keeping your tower in compliance with current FCC and FAA rules and regulations for day-marking is very important. All galvanized towers receive one top coat of industrial acrylic enamel #12197 organge and #17845 white paint mixed to comply with current Federal Specification on 595-A. Preferred Tank & Tower offers Poly-Urethane, Epoxy Mastic and Keeler & Long 4404 for custom paint applications.

Structural Analysis

Preferred Tank & Tower engineers are registered in more than 35 states. Our engineers have experience performing engineering on lattice type, self-supporting or guyed, steel towers and monopoles. Preferred Tank & Tower can handle modification to an HDTV installation.

Maintenance Service

Our range of services include: tower modifications, cathodic protection for anchor points, anchor replacement, periodic inspection and re-lamping, antennae and line work, earthquake modifications and 24 hour emergency service.

Tower Erection

Preferred Tank & Tower offers complete turnkey tower installations. We not only erect new and pre-owned towers for the cellular and wireless market but for broadcast, CATV and microwave applications as well. Professional Engineering services are readily available to handle foundation and structural issues.

Antenna and Line Installations

We offer complete antennae and line installation services. Our capabilities include installation of panel, omni-directional, high performance dishes, FM, yagis, HDTV and detuning skirts. Preferred Tank & Tower can install any type of line that these antennaes require. Line Sweeping services are also available.

Tower Lighting

Preferred Tank & Tower offers installation and maintenance of standard red obstruction tower lighting systems, medium intensity strobe systems, high intensity strobe systems and the popular medium intensity dual system. Preferred Tank & Tower will always keep a vigilant eye on any FAA/FCC updates that affect your compliance with these codes.

Inspection

Towers are visually inspected for compliance with applicable EIA, TIA, OSHA, and FAA/FCC requirements. The owner is furnished a written report and color photographs of unsatisfactory conditions with any minor corrections made at the time of inspection. Preferred Tank & Tower inspection crews carry state of the art equipment including laser range finders, used to determine precise AGL measurements and center of radiation levels, transits and dynometers.

Ultrasonic Inspection

Tubular legged towers can be inspected for interior corrosion using ultrasonic thinkness test equipment. This service can be used to provide data for our engineer's analysis of the tower's interior condition. This procedure can reveal deficiencies that would not be found by a visual inspection.

Tower Re-Lamping

Periodic re-lamping and inspection of lighting systems insure trouble-free operations and avoids costly fines.

 